MC_Stop, MCP_Stop – Stopping a movement
Block SymbolsLicensing group: MOTION CONTROL
Function Description
The MC_Stop and MCP_Stop blocks offer the same functionality, the only difference
is that some of the inputs are available as parameters in the MCP_ version of the
block.
The MC_Stop block commands a controlled motion stop and transfers the axis to the state Stopping. It aborts any ongoing Function Block execution. While the axis is in state Stopping, no other FB can perform any motion on the same axis. After the axis has reached velocity zero, the Done output is set to true immediately. The axis remains in the state Stopping as long as Execute is still true or velocity zero is not yet reached. As soon as Done=true and Execute=false the axis goes to state StandStill.
Note 1: parameter/input BufferMode is not supported. Mode is always Aborting.
Note 2: Failing stop-command could be dangerous. This block does not generate invalid-parameter-error but tries to stop the axis anyway (e.g. uses parameteres from RM_Axis or generates error-stop-sequence).
Inputs
uAxis | Axis reference (only RM_Axis.axisRef–uAxis or yAxis–uAxis connections are allowed | Reference |
Execute | The block is activated on rising edge | Bool |
Deceleration | Maximal allowed deceleration [unit/s] | Double (F64) |
Jerk | Maximal allowed jerk [unit/s] | Double (F64) |
Outputs
yAxis | Axis reference (only RM_Axis.axisRef–uAxis or yAxis–uAxis connections are allowed | Reference |
Done | Algorithm finished | Bool |
CommandAborted | Algorithm was aborted | Bool |
Busy | Algorithm not finished yet | Bool |
Active | The block is controlling the axis | Bool |
Error | Error occurred | Bool |
ErrorID | Result of the last operation | Error |
|
|
|