DIV – Division of two signals

Block SymbolLicensing group: STANDARD
PIC

Function Description
The DIV block divides two analog input signals y= u1u2. In case u2 = 0, the output E is set to onand the output y is substituted by y = yerr.

This block propagates the signal quality. More information can be found in the 1.4 section.

Input

u1

First analog input of the block

Double (F64)

u2

Second analog input of the block

Double (F64)

Parameter

yerr

Substitute value for an error case  1.0

Double (F64)

Output

y

Quotient of the inputs

Double (F64)

E

Error flag - division by zero

Bool

off ..

No error

on ...

An error occurred

2024 © REX Controls s.r.o., www.rexygen.com