MC_HaltSuperimposed, MCP_HaltSuperimposed – Stopping a movement (superimposed and interruptible)

Block SymbolsLicensing group: MOTION CONTROL
PIC PIC

Function Description

The MC_HaltSuperimposed and MCP_HaltSuperimposed blocks offer the same functionality, the only difference is that some of the inputs are available as parameters in the MCP_ version of the block.

Block MC_HaltSuperimposed commands a halt to all superimposed motions of the axis. The underlying motion is not interrupted.

Inputs

uAxis

Axis reference (only RM_Axis.axisRefuAxis or yAxisuAxis connections are allowed)

Reference

Execute

The block is activated on rising edge

Bool

Deceleration

Maximal allowed deceleration [unit/s2]

Double (F64)

Jerk

Maximal allowed jerk [unit/s3]

Double (F64)

Outputs

yAxis

Axis reference (only RM_Axis.axisRefuAxis or yAxisuAxis connections are allowed)

Reference

Done

Algorithm finished

Bool

CommandAborted

Algorithm was aborted

Bool

Busy

Algorithm not finished yet

Bool

Active

The block is controlling the axis

Bool

Error

Error occurred

Bool

ErrorID

Result of the last operation

Error