MC_ReadStatus – Read axis status
Block SymbolLicensing group: MOTION CONTROL
Function Description
The block MC_ReadStatus indicates the state of the connected axis on its logical output signals. The values of the states are valid only while the Enable input is set to nonzero value. This state is indicated by Valid output.
Inputs
uAxis | Axis reference (only RM_Axis.axisRef–uAxis or yAxis–uAxis connections are allowed) | Reference |
Enable | Block function is enabled | Bool |
Outputs
yAxis | Axis reference (only RM_Axis.axisRef–uAxis or yAxis–uAxis connections are allowed) | Reference |
Valid | Output value is valid | Bool |
Busy | Algorithm not finished yet | Bool |
Error | Error occurred | Bool |
ErrorID | Result of the last operation | Error |
|
|
|
ErrorStop | Axis is in the ErrorStop state | Bool |
Disabled | Axis is in the Disabled state | Bool |
Stopping | Axis is in the Stoping state | Bool |
StandStill | Axis is in the StandStill state | Bool |
DiscreteMotion | Axis is in the DiscreteMotion state | Bool |
ContinuousMotion | Axis is in the ContinuousMotion state | Bool |
SynchronizedMotion | Axis is in the SynchronizedMotion state | Bool |
Homing | Axis is in the Homing state | Bool |
ConstantVelocity | Axis is moving with constant velocity | Bool |
Accelerating | Axis is accelerating | Bool |
Decelerating | Axis is decelerating | Bool |
[Previous] [Back to top] [Up] [Next]
2024 © REX Controls s.r.o., www.rexygen.com