PROJECT – Additional Project Settings

Block SymbolLicensing group: STANDARD
PIC

Function Description
The PROJECT block is a so-called "pseudo-block" which stores additional settings and parameters related to a project and a real-time executive. The only file where the block can be placed is a main project file with a single EXEC block an so it belongs to the EXEC category.

The block does not have any inputs or outputs. The block does not become a part of the final binary configuration.

Parameters

CompileParams

Command-line options that are passed to REXYGEN Compiler during project compilation. To display the documentation for the available parameters, run REXYGEN Compiler from the command line with the parameter -?: RexComp -?.

String

SourcesOnTarget

Store source files on target device  on

Bool

TargetURL

URL address of a target on which the configuration should be run. The address is inserted into all connection dialogs automatically.

String

LibraryPath

Path to libraries referenced in the project. Can be absolute or relative to project folder.

String