SHIFTOCT – Data shift register
Block SymbolLicensing group: STANDARD
Function Description
The SHIFTOCT block works as a shift register with eight outputs of arbitrary data
type.
If the RUN input is active, the following assignment is performed with each algorithm tick:
Thus the value on each output y0 to y6 is shifted to the following output and the value on input u is assigned to output y0.
The block works with any data type of signal connected to the input u. Data type has to be specified by the vtype parameter. Outputs y0 to y7 then have the same data type.
If you need a triggered shift register, place the EDGE block in front of the RUN input.
This block propagates the signal quality. More information can be found in the 1.4 section.
Input
u | Analog input of the block | Any |
RUN | Enables outputs shift | Bool |
Parameter
vtype | Output data type 8 | Long (I32) |
|
|
|
Output
y0 | First analog output of the block | Any |
y1 | Second analog output of the block | Any |
y2 | Third analog output of the block | Any |
y3 | Fourth analog output of the block | Any |
y4 | Fifth analog output of the block | Any |
y5 | Sixth analog output of the block | Any |
y6 | Seventh analog output of the block | Any |
y7 | Eighth analog output of the block | Any |