BPF – Band-pass filter

Block SymbolLicensing group: STANDARD
PIC

Function Description
The BPF implements a second order filter in the form

Fs = 2ξas a2s2 + 2ξas + 1,

where a and ξ are are the block parameters fm and xi respectively. The fm parameter defines the middle of the frequency transmission band and xi is the relative damping coefficient.

If ISSF = on, then the state of the filter is set to the steady value at the block initialization according to the input signal u.

This block propagates the signal quality. More information can be found in the 1.4 section.

Input

u

Input signal to be filtered

Double (F64)

R1

Block reset

Bool

HLD

Hold

Bool

Parameter

fm

Peak frequency [Hz]  1.0

Double (F64)

xi

Relative damping coefficient  0.707

Double (F64)

ISSF

Steady state at start-up

Bool

off ..

Zero initial state

on ...

Initial steady state

Output

y

Filtered output signal

Double (F64)

2024 © REX Controls s.r.o., www.rexygen.com